Physics 9702 · Chapter 24 of 25
Medical physics
97 Cambridge A Level Physics (9702) past-paper questions on Medical physics, across 3 subtopics, with official mark schemes.
Subtopics
- Production and use of ultrasound59 questions
- Production and use of X-rays23 questions
- PET scanning1 questions
Medical physics questions by year and paper
How often Medical physics has come up in Cambridge A Level Physics (9702) exams. The busiest years were 2021 (8 questions), 2023 (6 questions), 2022 (6 questions). Every count links back to real sittings in the yearly past papers.
| Year | Paper 4 | Total |
|---|---|---|
| 2026 | 2 | 2 |
| 2025 | 4 | 4 |
| 2024 | 2 | 2 |
| 2023 | 6 | 6 |
| 2022 | 6 | 6 |
| 2021 | 8 | 8 |
| 2020 | 6 | 6 |
| 2019 | 4 | 4 |
| 2018 | 6 | 6 |
| 2017 | 6 | 6 |
| 2016 | 6 | 6 |
| 2015 | 3 | 3 |
| 2014 | 4 | 4 |
| 2013 | 5 | 5 |
| 2012 | 6 | 6 |
| 2011 | 3 | 3 |
| 2010 | 6 | 6 |
Latest exam questions on Medical physics
The most recent 12 questions on this chapter, newest first. Build a booklet to get every one of them with its official mark scheme.
- 9702/44 · May/June 2026 · Question 9
(a) Explain how ultrasound waves are generated by a piezoelectric transducer. (b) Ultrasound waves are used to obtain information about a structure that consists of two materials, as shown in Figure 9.1. ultrasound waves …
- 9702/42 · Feb/March 2026 · Question 10
(a) (i) Explain how ultrasound waves are detected by a piezoelectric transducer. (ii) Define the specific acoustic impedance of a medium. (b) Table 10.1 lists the specific acoustic impedances Z of air, water and …
- 9702/41 · Oct/Nov 2025 · Question 10
(a) Define specific acoustic impedance. (b) Explain how ultrasound waves are detected by a piezoelectric crystal. (c) Table 10.1 shows the specific acoustic impedance Z for body tissue, water and steel. Table 10.1 material …
- 9702/42 · Oct/Nov 2025 · Question 10
(a) State what is meant by contrast in an X-ray image. (b) X-rays of intensity I0 are incident normally on a structure, as shown in Fig. …
- 9702/43 · Oct/Nov 2025 · Question 10
(a) Define specific acoustic impedance. (b) Explain how ultrasound waves are detected by a piezoelectric crystal. (c) Table 10.1 shows the specific acoustic impedance Z for body tissue, water and steel. Table 10.1 material …
- 9702/44 · May/June 2025 · Question 10
(a) Describe how the piezoelectric crystal in a transducer generates ultrasound waves for use in medical diagnosis. (b) A parallel ultrasound beam is incident on the boundary between two media, as illustrated in Fig. …
- 9702/42 · May/June 2024 · Question 10
(a) Describe how reflected ultrasound pulses may be used to obtain diagnostic information about internal structures. (b) (i) Define specific acoustic impedance of a medium. (ii) Table 10.1 shows some data for water and …
- 9702/42 · Feb/March 2024 · Question 9
(a) Electrons in a vacuum are accelerated through a potential difference of 84 kV. The electrons then strike a metal target and X‑rays are produced. (i) Calculate the minimum wavelength of the X‑rays that …
- 9702/41 · Oct/Nov 2023 · Question 10
Ultrasound and X-rays are both types of wave that are used in medical diagnosis to form images of internal body structures. (a) Complete Table 10.1 to state, for each type of wave: ● the …
- 9702/43 · Oct/Nov 2023 · Question 10
Ultrasound and X-rays are both types of wave that are used in medical diagnosis to form images of internal body structures. (a) Complete Table 10.1 to state, for each type of wave: ● the …
- 9702/41 · May/June 2023 · Question 8
(a) Table 8.1 shows some data relating to the properties of air, gel and body tissue. The data are given to three significant figures. Table 8.1 material density / kg m–3 speed of sound …
- 9702/42 · May/June 2023 · Question 10
(a) X-rays for use in medical diagnosis are produced in an X-ray tube. In the X-ray tube, charged particles are accelerated towards a metal target by an applied potential difference (p.d.). (i) State the …
Key terms examiners use
- X-ray imaging
- CT scan
- PET scan
- ultrasound imaging
- MRI
- attenuation coefficient
- I = I0 e
- acoustic impedance
- ultrasound pulse
- reflection coefficient
- piezoelectric
- resolution
- contrast
- radiation exposure
- radiotracer
- half-thickness
- transmitted intensity
- the image is formed